80 research outputs found

    Theory and analysis of electrode size optimization for capacitive microfabricated ultrasonic transducers

    Get PDF
    Cataloged from PDF version of article.Theoretical analysis and computer simulations of capacitive microfabricated ultrasonic transducers indicate that device performance can be optimized through judicious patterning of electrodes. The conceptual basis of the analysis is that electrostatic force should be applied only where it is most effective, such as at the center of a circular membrane. If breakdown mechanisms are ignored, an infinitesimally small electrode with an infinite bias voltage results in the optimal transducer, A more realistic design example compares the 3-dB bandwidths of a fully metalized transducer and a partially metalized transducer, each tuned with a lossless Butterworth network. It is found that the bandwidth of the optimally metalized device is twice that of the fully metalized device

    Surface micromachined capacitive ultrasonic transducers

    Get PDF
    Cataloged from PDF version of article.The current state of a novel technology, surface microfabricated ultrasonic transducers, is reported. Experiments demonstrating both air and water transmission are presented. Air-coupled longitudinal wave transmission through aluminum is demonstrated, implying a 110 dB dynamic range for transducers at 2.3 MHz in air. Water transmission experiments from 1 to 20 MHz are performed, with a measured 60 dB SNR at 3 MHz. A theoretical model is proposed that agrees well with observed transducer behavior. Most significantly, the model is used to demonstrate that microfabricated ultrasonic transducers constitute an attractive alternative to piezoelectric transducers in many applications

    Prevalence and Clinical Features of Sessile Serrated Polyps: A Systematic Review

    Get PDF
    Background & Aims: Sessile serrated polyps (SSPs) could account for a substantial proportion of colorectal cancers. We aimed to increase clarity on SSP prevalence and clinical features. Methods: We performed a systematic review of MEDLINE, Web of Science, Embase, and Cochrane databases for original studies published in English since 2000. We included studies of different populations (United States general or similar), interventions (colonoscopy, autopsy), comparisons (world regions, alternative polyp definitions, adenoma), outcomes (prevalence, clinical features), and study designs (cross-sectional). Random-effects regression was used for meta-analysis where possible. Results: We identified 74 relevant colonoscopy studies. SSP prevalence varied by world region, from 2.6% in Asia (95% confidence interval [CI], 0–5.9) to 10.5% in Australia (95% CI, 2.8–18.2). Prevalence values did not differ significantly between the United States and Europe (P = .51); the pooled prevalence was 4.6% (95% CI, 3.4–5.8), and SSPs accounted for 9.4% of polyps with malignant potential (95% CI, 6.6–12.3). The mean prevalence was higher when assessed through high-performance examinations (9.1%; 95% CI, 4.0–14.2; P = .04) and with an alternative definition of clinically relevant serrated polyps (12.3%; 95% CI, 9.3–15.4; P < .001). Increases in prevalence with age were not statistically significant, and prevalence did not differ significantly by sex. Compared with adenomas, a higher proportion of SSPs were solitary (69.0%; 95% CI, 45.9–92.1; P = .08), with diameters of 10 mm or more (19.3%; 95% CI, 12.4–26.2; P = .13) and were proximal (71.5%; 95% CI, 63.5–79.5; P = .008). The mean ages for detection of SSP without dysplasia, with any or low-grade dysplasia, and with high-grade dysplasia were 60.8 years, 65.6 years, and 70.2 years, respectively. The range for proportions of SSPs with dysplasia was 3.7%–42.9% across studies, possibly reflecting different study populations. Conclusions: In a systematic review, we found that SSPs are relatively uncommon compared with adenoma. More research is needed on appropriate diagnostic criteria, variations in detection, and long-term risk

    Air-coupled, focused ultrasonic dispersion spectrum reconstruction in plates

    Get PDF
    This paper presents and demonstrates a noncontact method for measuring the Lamb wave dispersion spectrum of a plate. Noncontact air-coupled source and receive transducers are used with line-focus mirrors and 50–700 kHz broadband apparatus for simultaneous measurement over a broad spectrum of refractive angles and multiple guided modes. Broadband, wide-angle wave forms are measured as a function of position. The Fourier transform of these wave forms from the t – x domain to the v – k domain gives an approximate spectrum of the dispersion relation. We measure the dispersion spectra of Lucite™, aluminum, balsa wood, and a carbon fiber epoxy laminate, and show that the measured spectra agree well with the dispersion relation calculated from Lamb wave theory

    The dopaminergic system in patients with functional dyspepsia analysed by single photon emission computed tomography (SPECT) and an alpha-methyl-para-tyrosine (AMPT) challenge test

    Get PDF
    Functional dyspepsia (FD) is a chronic condition characterized by upper abdominal symptoms without an identifiable cause. While the serotonergic system is thought to play a key role in the regulation of gut physiology, the role of the dopaminergic system, which is important in the regulation of visceral pain and stress, is under-studied. Therefore, this study investigated the dopaminergic system and its relationship with drinking capacity and symptoms in FD patients. In FD patients and healthy volunteers (HV) the dopaminergic system was investigated by in-vivo assessment of central dopamine D2 receptors (D2Rs) with [I-123]IBZM SPECT and by an acute, but reversible, dopamine depletion alpha-methyl-para-tyrosine (AMPT) challenge test. A nutrient drink test was performed to investigate the association between maximal ingested volume, evoked symptoms, and D2Rs. The HV subjects comprised 12 women and 8 men (mean age 31 +/- 3 years), and the FD patients comprised 5 women and 3 men (mean age 39 +/- 5 years). The FD patients had a lower left plus right average striatal binding potential (BPNP) for the caudate nucleus (p = 0.02), but not for putamen (p = 0.15), which in the FD patients was correlated with maximal ingested volume (r = 0.756, p = 0.03). The D2R BPNP in the putamen was correlated with nausea (r = 0.857, p = 0.01). The acute dopamine depletion test, however, failed to reveal differences in prolactin release between the FD patients and the HV subjects. These preliminary data suggest that chronic rather than acute alterations in the dopaminergic system may be involved in the pathogenesis of FD. Further studies are required to reproduce our novel findings and to evaluate to what extent the dopaminergic changes may be secondary to abnormalities in serotonergic pathway

    Effectiveness and costs of implementation strategies to reduce acid suppressive drug prescriptions: a systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Evaluation of evidence for the effectiveness of implementation strategies aimed at reducing prescriptions for the use of acid suppressive drugs (ASD).</p> <p>Methods</p> <p>A systematic review of intervention studies with a design according to research quality criteria and outcomes related to the effect of reduction of ASD medication retrieved from Medline, Embase and the Cochrane Library. Outcome measures were the strategy of intervention, quality of methodology and results of treatment to differences of ASD prescriptions and costs.</p> <p>Results</p> <p>The intervention varied from a single passive method to multiple active interactions with GPs. Reports of study quality had shortcomings on subjects of data-analysis. Not all outcomes were calculated but if so rction of prescriptions varied from 8% up to 40% and the cost effectiveness was in some cases negative and in others positive. Few studies demonstrated good effects from the interventions to reduce ASD.</p> <p>Conclusion</p> <p>Poor quality of some studies is limiting the evidence for effective interventions. Also it is difficult to compare cost-effectiveness between studies. However, RCT studies demonstrate that active interventions are required to reduce ASD volume. Larger multi-intervention studies are necessary to evaluate the most successful intervention instruments.</p

    Does CT colonography have a role for population-based colorectal cancer screening?

    Get PDF
    Colorectal cancer (CRC) is the second most common cancer and second most common cause of cancer-related deaths in Europe. CRC screening has been proven to reduce disease-specific mortality and several European countries employ national screening programmes. These almost exclusively rely on stool tests, with endoscopy used as an adjunct in some countries. Computed tomographic colonography (CTC) is a potential screening test, with an estimated sensitivity of 88 % for advanced neoplasia ≥10 mm. Recent randomised studies have shown that CTC and colonoscopy have similar yields of advanced neoplasia per screened invitee, indicating that CTC is potentially viable as a primary screening test. However, the evidence is not fully elaborated. It is unclear whether CTC screening is cost-effective and the impact of extracolonic findings, both medical and economic, remains unknown. Furthermore, the effect of CTC screening on CRC-related mortality is unknown, as it is also unknown for colonoscopy. It is plausible that both techniques could lead to decreased mortality, as for sigmoidoscopy and gFOBT. Although radiation exposure is a drawback, this disadvantage may be over-emphasised. In conclusion, the detection characteristics and acceptability of CTC suggest it is a viable screening investigation. Implementation will depend on detection of extracolonic disease and health-economic impact

    The evidence base for circulating tumour DNA blood-based biomarkers for the early detection of cancer: a systematic mapping review

    Get PDF
    Background: The presence of circulating cell-free DNA from tumours in blood (ctDNA) is of major importance to those interested in early cancer detection, as well as to those wishing to monitor tumour progression or diagnose the presence of activating mutations to guide treatment. In 2014, the UK Early Cancer Detection Consortium undertook a systematic mapping review of the literature to identify blood-based biomarkers with potential for the development of a non-invasive blood test for cancer screening, and which identified this as a major area of interest. This review builds on the mapping review to expand the ctDNA dataset to examine the best options for the detection of multiple cancer types. Methods: The original mapping review was based on comprehensive searches of the electronic databases Medline, Embase, CINAHL, the Cochrane library, and Biosis to obtain relevant literature on blood-based biomarkers for cancer detection in humans (PROSPERO no. CRD42014010827). The abstracts for each paper were reviewed to determine whether validation data were reported, and then examined in full. Publications concentrating on monitoring of disease burden or mutations were excluded. Results: The search identified 94 ctDNA studies meeting the criteria for review. All but 5 studies examined one cancer type, with breast, colorectal and lung cancers representing 60% of studies. The size and design of the studies varied widely. Controls were included in 77% of publications. The largest study included 640 patients, but the median study size was 65 cases and 35 controls, and the bulk of studies (71%) included less than 100 patients. Studies either estimated cfDNA levels non-specifically or tested for cancer-specific mutations or methylation changes (the majority using PCR-based methods). Conclusion: We have systematically reviewed ctDNA blood biomarkers for the early detection of cancer. Pre-analytical, analytical, and post-analytical considerations were identified which need to be addressed before such biomarkers enter clinical practice. The value of small studies with no comparison between methods, or even the inclusion of controls is highly questionable, and larger validation studies will be required before such methods can be considered for early cancer detection
    corecore